Osteoarthritis of the ankle after foreign-body reaction of absorbable pins and screws: A three- to nine-year follow-up study

Bostman, O M

Between 1985 and 1994,1223 patients with malleolar fractures of the ankle were treated by open reduction and internal fixation with absorbable pins and screws, of whom 74 (6.1 %) had an obvious inflammatory foreign-body reaction to the implants. Of these 74, ten later developed moderate to severe osteoarthritis of the ankle despite no evidence of incongruity of the articular surface. The implants used in these patients were made from polyglycolide, polylactide or glycolide-lactide copolymer

The joint damage seemed to be due to polymeric debris entering the articular cavity through an osteolytic extension of an implant track. The ten patients had a long clinical course which included a vigorous local foreign-body reaction, synovial irritation and subsequent degeneration. At a follow-up of three to nine years, ankle arthrodesis had been necessary in two patients and is being considered for another two.

The incidence of these changes in the whole series was 0.8%, which is not high, but awareness of this possible late complication is essential.

J Bone Joint Surg [Br] 1998;80-B:333-8.

Received 21 August 1997; Accepted after revision 4 November 1997

Soon after the large-scale introduction of absorbable implants for the internal fixation of fractures in the late 1980s, it was found that they were occasionally associated with an inflammatory foreign-body reaction at the site of implantation.1-7 The characteristic features were osteolysis in cancellous bone seen around the implant and sterile skin sinuses discharging remnants of the fixation devices.8-12 In the short term, this complication was regarded as benign and transient, occurring after union of the fracture, and not resulting in permanent tissue changes.1,8

With greater experience of absorbable implants it is necessary to change that view. We report ten patients with foreign-body reactions to implants for internal fixation made from synthetic biodegradable a-hydroxypolyesters, who developed irreversible damage to the ankle.

Patients and Methods

From January 1985 to June 1994 we used absorbable pins and screws for the internal fixation of displaced malleolar fractures in 1223 patients (Table I). All the implants were produced by the same manufacturer (Bioscience, Tampere, Finland). During the first year, they were made from glycolide-lactide copolymer (PGA-PLA) in a ratio of 90:10. Later, pure polyglycolide (PGA) replaced the copolymer, and from 1989 they were made also from pure poly-Llactide (PLA). The degradation time of PGA is a few months, whereas that of PLA in stereo-isomeric laevo form is several years. The two types of material were sometimes used together in the treatment of one injury (Table I). An example of this is a patient with a trimalleolar fracture: the malleoli were fixed with PLA screws, and the distal tibiofibular syndesmosis was stabilised with a PGA pin.

All the implants were inserted into extra-articular predrilled channels of the same diameter, and the drill-holes for screws were tapped. The drill-holes were made in the usual places recommended for metal internal fixation13 and cast immobilisation was used for six weeks after operation.

There was an obvious foreign-body reaction in 74 of the 1223 patients (6.1%), first seen as a painful erythematous papule or a discharging sinus at a median time of 11 weeks (7 to 18) after operation. Treatment was by aspiration of subcutaneous accumulations of tissue exudate and excision or debridement of discharging sinuses. In most cases, this resulted in the disappearance of the reaction within five weeks. During later years, however, some patients developed more prolonged symptoms with sterile synovitis and increasing pain.

We have studied ten such patients with joint involvement after a foreign-body reaction. At the latest assessment the mean follow-up was 49.6 months (36 to 109). We excluded patients with incongruity of the articular surface due to an inaccurate reduction or late mechanical failure of the fixation. To set this finding in context, we scrutinised the records of all the 1213 remaining patients for late referrals or visits. Because of the experimental nature of this method of treatment, which was known to doctors in the catchment area, patients with complications were usually referred to us without delay.

Moderate osteoarthritis was diagnosed when there was pain, limited ankle movement and joint-space narrowing on plain radiographs to 50% or more of the original values.14 When there was subtotal disappearance of the joint space, severe osteoarthritis was diagnosed.15

Continuous data were analysed by the Mann-Whitney U test and categorical data by the chi-squared test or Fisher’s exact test.

Results

Clinical. In the ten patients, the delay between the operation and the first signs of a foreign-body reaction (Table II) did not differ from that in the other 64 patients having a foreign-body reaction. All ten had developed a sinus discharging tissue exudate and polymeric debris within a few days. In seven of them, this was on both the lateral and the medial sides of the ankle. Bacterial cultures from the exudate showed no growth.

The first clinical signs of synovitis in the ankle appeared during the following weeks, but aspiration was avoided because of the danger of spreading secondary infection from open sinuses into the joint. By the time synovitis was evident, nine of the ten patients had union of their fractures (Fig. 1). Three patients required inpatient care for acute inflammatory reaction and two had debridement under general anaesthesia. One patient (case 3) required a skin graft for extensive sloughing over the lateral malleolus (Fig. 2). Biopsy specimens taken from the soft tissues at debridement operations showed changes typical of a nonspecific foreign-body reaction, with abundant polymeric particles phagocytosed by multinucleated foreign-body giant cells.

In all ten patients, the acute reaction had subsided after four months, and was replaced by clinical and radiological signs of osteoarthritis (Figs I and 3). The median delay between injury and the diagnosis of osteoarthritis was 11 months (7 to 15). To date, two patients have had ankle arthrodeses (Table II), and this is being considered for two others.

Radiology. Plain radiographs at the onset of the tissue reaction showed osteolytic changes with cystic extensions of the implant tracks in all ten patients (Fig. 1 ). The fracture was ununited in only one patient (Fig. 2). Communication between one or several of the enlarged, extraarticular implant tracks and the ankle seems likely (Figs 1 and 2). The osteolysis regressed during a three-year period (Fig. 1), but the osteoarthritic changes increased (Figs I and 3).

Statistics. The incidence of joint involvement, ten of 1223 patients, was 0.8% (95% confidence interval (CI) 0.3 to 1.5%). In the 74 patients with obvious foreign-body reactions the incidence was 13.5% (95% CI 6.7 to 24.5%). We found no statistically significant differences in the mean age or male-to-female ratio between the whole population with ankle fractures and absorbable implants and those developing articular damage, but patients with bi- or trimalleolar fractures were significantly over-represented in the osteoarthritic group (p = 0.03). A total of 1108 patients had an accurate reduction and no obvious foreign-body reaction, and none of them has required ankle arthrodesis. Two of the 74 patients with a foreign-body reaction have already needed this; the difference is highly significant (p = 0.004).

Discussion

Concerns have already been expressed about the biocompatibility of these absorbable implants3,5-7,10,16,17 despite the lack of long-term clinical data on large series. We found that the use of absorbable alpha-hydroxypolyester pins and screws for the internal fixation of displaced malleolar fractures led to an incidence of osteoarthritic changes in the ankle of approximately 1%, probably initiated by foreign-body reactions. This incidence is quite low, but the complication is a severe one, and thousands of patients are treated for these common types of fracture. After conventional metal internal fixation, the development of osteoarthritis is associated with inaccurate reduction and subsequent malunion18,19 but we excluded such cases. We saw no severe osteoarthritis in patients treated with absorbable implants and accurate reduction, unless a foreign-body reaction had complicated the course.

All the ten patients affected had osteolytic lesions which seemed to communicate with the joint space. Although it was not possible to confirm it histologically, the dissemination of polymeric debris and inflammatory cells into the joint seemed to cause permanent damage to the articular surfaces. Acute synovitis of the knee has been described in three patients after fixation of osteochondral fragments with PGA pins,5,6 but there was no long-term follow-up. The association between osteolytic changes and foreign-body tissue responses to PGA has been well documented in experimental20,21 and clinical studies,8,10,11,22 but the natural history of such lesions is not clear. We have confirmed in our study that there is usually total regression of the osteolysis within three years.

PGA is a relatively inert polymer in immunological terms,23 but PLA implants are suspected of activating the plasma complement system,16 although there is a divergence of opinion on the significance of the finding.24 An osteolytic foreign-body response can occur without any immunologically-mediated mechanism; a non-specific macrophage activation suffices. Non-degradable polymeric particles are known to activate macrophages and cause osteolysis and bone resorption.25

Fixation devices made from PLA were introduced several years after PGA devices, and at the completion of our study no cases of articular damage had been found in the patients who had exclusively PLA devices. Despite this, PLA implants have been found to elicit foreign-body reactions,2,26 but because of the long degradation time of PLA, these were seen only three to five years after operation. When more patients are operated on using PLA it is possible that similar but late joint involvement will be seen.

The biocompatibility of these materials is important: absorbable polyesters are likely to become increasingly used in other fields of orthopaedic surgery. These include interference screw fixation for reconstruction of the anterior cruciate ligament, anchoring the acetabular component in total hip replacements and arthroscopic fixation of buckethandle meniscal lesions. 27-29 The true risk of surgical innovation is often found only after extensive clinical experience, because animal experiments are not always valid for all the biological aspects of clinical practice.

It is therefore important that all complications should be reported, especially those associated with enthusiastically marketed surgical novelties. A recent editorial in the Lancet30 advised surgeons not to ally themselves too closely with manufacturers, since the latter do not seek technically and scientifically proven methods but are more interested in profit.

Absorbable fixation devices, certainly those made from PGA, should not be used near joint spaces since a foreignbody reaction may risk the intra-articular dissemination of polymeric debris. Our current study could not show the pathogenesis of the onset of osteoarthritis, and did not investigate it at the cellular level. More research is needed on the basic chemistry and physics of biodegradable polymers, and further long-term clinical studies are necessary to evaluate both the intraosseous and intra-articular biocompatibility of such devices.

This study was supported by a grant from the Helsinki University Hospital Research Funds.

One or more of the authors have received or will receive benefits for personal or professional use from a commercial party related directly or indirectly to the subject of this article. In addition benefits have also been or will be directed to a research fund, foundation, educational institution, or other non-profit institution with which one or more of the authors is associated.

References

1. Bostman O, Hirvensalo E, Makinen J, Rokkanen P. Foreign body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg [Br] 1990:72-B:592-6.

2. Eitenmuller J, David A, Pommer A, Muhr G. Die Versorgung von Sprunggelenksfrakturen unter Verwendung von Platten und Schrauben aus resorbierbarem Polymer-Material. Hefte zur Unfallheilk 1990;212: 440-3.

3. Poigenfurst J, Leixnering M, Ben Mokhtar M. Local complications following implantation of Biorod. Aktuelle Traumatol 1990;20: 157-9.

4. Bostman OM. Current concepts review: absorbable implants for the fixation of fractures. J Bone Joint Surg [Am] 1991;73-A:148-53.

5. Barfod G, Svendsen RN. Synovitis of the knee after intraarticular fracture fixation with Biofix: report of two cases. Acta Orthop Scand 1992;63:680-1.

6. Friden T, Rydholm U. Severe aseptic synovitis of the knee after biodegradable internal fixation. Acta Orthop Scand 1992;63:94-7.

7. Frokjaer J, Moller BN. Biodegradable fixation of ankle fractures: complications in a prospective study of 25 cases. Acta Orthop Scand 1992;63:434-6.

8. Bostman OM. Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg [Br] 1991; 73-B:679-82.

9. Bostman OM. Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures. Clin Orthop 1992;278:193-9.

10. Casteleyn PP, Handelberg F, Haentjes P. Biodegradable rods versus Kirschner wire fixation of wrist fractures: a randomised trial. J Bone Joint Surg [Br] 1992;74-B:858-61.

11. Fraser RK, Cole WG. Osteolysis after biodegradable pin fixation in children. J Bone Joint Surg [Br] 1992;74-B:929-30.

12. Hoffmann R, Krettek C, Hetkamper A, Haas N, Tscherne H. Osteosynthesis of distal radius fractures with biodegradable fracture rods: results of 2 years’ follow-up. Unfallchirurg 1992;95:99-105.

13. Miller ME, Allgower M, Schneider R, Willenegger H. Manual of internal fixation: techniques recommended by the AO-ASIF group. 3rd ed. Berlin: Springer-Verlag, 1991:595-612.

14. Jonsson K, Fredin HO, Cederlund CG, Bauer M. Width of the normal ankle joint. Acta Radiol Diagn Stockh 1984;25:147-9.

15. Niek van Dijk C, Verhagen RAW, Tol JL. Arthroscopy for problems after ankle fracture. J Bone Joint Surg[Br] 1997;79-B:280-4.

16. Tegnander A, Engebretsen L, Bergh K, et al. Activation of the complement system and adverse effects of biodegradable pins of polylactic acid (Biofix) in osteochondritis dissecans. Acta Orthop Scand 1994;65:472-5.

17. Hovis WD, Bucholz RW. Polyglycolide bioabsorbable screws in the treatment of ankle fractures. Foot Ankle Int 1997; 18:128-31.

18. Lindsjo U. Operative treatment of ankle fracture dislocations: a follow-up study of 306/321 consecutive cases. Clin Orthop 1985; 199:28-38.

19. Phillips WA, Schwartz HS, Keller CS, et al. A prospective, randomized study of the management of severe ankle fractures. J Bone Joint Surg [Am] 1985;67-A:67-78.

20. Bostman O, Paivarinta U, Partio E, et al. Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies. J Bone Joint Surg [Am] 1992;74-A: 1021-31.

21. Weiler A, Hell-ing HJ, Kirch U, Zirbes TK, Rehm KE. Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: experimental study in sheep. J Bone Joint Surg [Br] 1996:78-B:369-76.

22. Svensson PJ, Janarv PM, Hirsch G. Internal fixation with biodegradable rods in pediatric fractures: one year follow-up of fifty patients. J Pediatr Orthop 1994;14:220-4.

23. Santavirta S, Konttinen YT, Saito T, et al. Immune response to polyglycolic acid implants. J Bone Joint Surg [Br] 1990;72-B: 597-600.

24. Mainil-Varlet P. Polylactic acid pins (letter). Acta Orthop Scand 1995; 66:573-4.

25. Murray DW, Rushton N. Macrophages stimulate bone resorption when they phagocytose particles. J Bone Joint Surg [Br] 1990; 72-B:988-92.

26. Bergsma EJ, de Bruijn WC, Rozema FR, Bos RR, Boering G. Late degradation tissue response to poly(L-lactide) bone plates and screws. Biomaterials 1995;16:25-31.

27. Kristensen G, Albrecht-Olsen P, Burgaard P, Jorgensen U, Torholm C. Biofix -meniscus tacks versus inside-out suturing technique in the treatment of bucket-handle lesions: a randomized study. Acta Orthop Stand 1994:65:Suppl 260:17.

28. Thanner J, Karrholm J, Malchau H, Wallinder L, Herberts P. Migration of press-fit cups fixed with poly-L-lactic acid or titanium screws: a randomised study using radiostereometry. J Orthop Res 1996:14:895-900.

29. Tuompo P, Partio E, Rokkanen P. Absorbable fixation in bonetendon-bone reconstruction of anterior cruciate ligament. J Bone Joint Surg [Br] 1997;79-B:Suppl II:189.

30. Anonymous. Editorial. Surgical innovation under scrutiny. Lancet 1993;342:187-8.

O. M. Bostmam MD, PhD, Orthopaedic Surgeon Department of Orthopaedic and Trauma Surgery, Helsinki University Hospital, Topeliuksenkatu 5, FIN-00260 Helsinki, Finland.

O. M. Bostman From Helsinki University Hospital, Finland

Copyright British Editorial Society of Bone & Joint Surgery Mar 1998

Provided by ProQuest Information and Learning Company. All rights Reserved